Product Feature:
LE series aluminum alloy guide rail type magnetostrictive displacement sensor, which is suitable for the external linear displacement measuring installation.Electronic product head part of the total internal in aluminum profile, supporting the magnetic slider sliding all the way, even if the slider accident beyond range will not damage the sensor, is suitable for the position measuring vibration large nc equipment.External installation, compact structure, easy to use.
Including: optional output signal, SSI, and other forms, can be widely used in all kinds of CNC machine tools, such as stamping machines, building materials machinery, woodworking machinery, etc.
Technical Parameters:
Analog Output | SSI Output | |
---|---|---|
Project Name | Standard/Parameter | Standard/Parameter |
Measurement Range | 50-4500mm | 50-4500mm |
Output Signal | 0~20mA,4~20mA; 0~10V,-10~+10V | 24,25,26 bit binary system or Gray code |
Resolution | 16 bit D/A | 2/ 5/ 10/ 20/ 50/100um |
Non-linearity | <±0.01%F.S.(min±50μm) | <±0.01%F.S.(min±40μm) |
Repeatability | <±0.002%F.S.(min±2μm) | <±0.002%F.S.(min±1 readings) |
Response Frequency | Related to the range | Related to the range |
Operating Voltage | 24VDC (-15/+20%) | |
Working Temp | - 40℃~+85℃ | |
Protective Ability | IP65 | |
Way To Install | Tingle,match M5X20 Full dog point socket set use |
Boundary Dimension:
V slider magnet |
---|
V-shaped suspension magnet |
---|
Electrical Connection:
Analog Output | Needle Size | Line Color | Definition | SSI Output | Needle Size | Line Color | Definition |
---|---|---|---|---|---|---|---|
1 | grey | Output Signal:0-20mA,0-10V | 1 | grey | (-)data | ||
2 | pink | Signal earth | 2 | pink | (+) data | ||
3 | yellow | (+)communication interface | 3 | yellow | (+) clock | ||
4 | green | (-)communication interface | 4 | green | (-) clock | ||
5 | palm | +24VDC(±10%) | 5 | palm | +24VDC(±10%) | ||
6 | white | A direct current source | 6 | white | A direct current source | ||
7 | throw out of gear |
Analog Output | Needle Size | Line Color | Definition | Modbus Output | Needle Size | Line Color | Definition |
---|---|---|---|---|---|---|---|
1 | grey | Output Signal:4-20mA,0-10V | 1 | grey | A(RS485) | ||
2 | pink | Signal earth | 2 | pink | B(RS485) | ||
3 | palm | +24VDC(±10%) | 3 | palm | +24VDC(±10%) | ||
4 | white | A direct current source | 4 | white | A direct current source |
Analog Output | Indicator state | Definition |
---|---|---|
Green light | Regular work | |
Green light flashing | Programme state | |
Red light flashing | The circular leave effective range | |
Red light | Detect the circular or damage |
SSI 輸出 | Indicator state | Definition |
---|---|---|
Green light | Regular work | |
Green light flashing | Programme state | |
Red light flashing | The circular leave effective range | |
Red light | Detect the circular or damage |